Passive, gravity-driven thermosyphons represent a stepchange in technology towards the goal of greatly reducing PUE (Power Usage Effectiveness) of datacenters by replacing energy hungry fans of air-cooling approach with a highly-reliable solution able to d ...
Cooling the surface of freshwater bodies, whose temperatures are above the temperature of maximum density, can generate differential cooling between shallow and deep regions. When surface cooling occurs over a long enough period, the thermally induced cros ...
This paper provides accurate analytic models for a computationally efficient estimation of the natural con- vection cooling coefficients for typical geometries, such as those encountered in transformers. Proper thermal coordination is an essential step of ...
The use of evaporative cooling in the gas diffusion layer (GDL) of polymer electrolyte fuel cells has been proposed as a simple yet impactful solution to simultaneously provide the functionality of cell cooling, thanks to the dissipation of the latent heat ...