Tokamakthumb|Vue intérieure du tore du Tokamak à configuration variable (TCV), dont les parois sont recouvertes de tuiles de graphite. Un tokamak est un dispositif de confinement magnétique expérimental explorant la physique des plasmas et les possibilités de produire de l'énergie par fusion nucléaire. Il existe deux types de tokamaks aux caractéristiques sensiblement différentes, les tokamaks traditionnels toriques (objet de cet article) et les tokamaks sphériques.
Neutral-beam injectionNeutral-beam injection (NBI) is one method used to heat plasma inside a fusion device consisting in a beam of high-energy neutral particles that can enter the magnetic confinement field. When these neutral particles are ionized by collision with the plasma particles, they are kept in the plasma by the confining magnetic field and can transfer most of their energy by further collisions with the plasma. By tangential injection in the torus, neutral beams also provide momentum to the plasma and current drive, one essential feature for long pulses of burning plasmas.
Fusion par confinement magnétiqueLa fusion par confinement magnétique (FCM) est une méthode de confinement utilisée pour porter une quantité de combustible aux conditions de température et de pression désirées pour la fusion nucléaire. De puissants champs électromagnétiques sont employés pour atteindre ces conditions. Le combustible doit au préalable être converti en plasma, celui-ci se laisse ensuite influencer par les champs magnétiques. Il s'agit de la méthode utilisée dans les tokamaks toriques et sphériques, les stellarators et les machines à piège à miroirs magnétiques.
Reconnexion magnétiquedroite|vignette|380px|Reconnexion magnétique: Ce schéma est une coupe à travers quatre domaines magnétiques séparés par une interface propice à un phénomène de reconnexion. Deux séparatrices (voir texte) divisent l'espace en quatre domaines magnétiques avec un point critique (de stagnation) au centre de la figure. Les larges flèches jaunes indiquent le mouvement général du plasma. Les lignes magnétiques et le plasma qui les porte s'écoulent vers le centre à partir du haut (lignes rouges) et du bas (lignes bleues) de l'image, reconnectent au niveau de la zone critique, puis s'évacuent vers l'extérieur à gauche et à droite.
ITERLe réacteur thermonucléaire expérimental international, ou ITER (acronyme de l'anglais International thermonuclear experimental reactor, également mot latin signifiant « chemin » ou « voie »), est un projet international de réacteur nucléaire de recherche civil à fusion nucléaire de type tokamak, situé à proximité immédiate du centre d’études nucléaires de Cadarache à Saint-Paul-lez-Durance (Bouches-du-Rhône, France). Le projet de recherche s'inscrit dans une démarche à long terme visant à l'industrialisation de la fusion nucléaire.
Énergie de fusion nucléairevignette| L'expérience de fusion magnétique du Joint European Torus (JET) en 1991. L'énergie de fusion nucléaire est une forme de production d'électricité du futur qui utilise la chaleur produite par des réactions de fusion nucléaire. Dans un processus de fusion, deux noyaux atomiques légers se combinent pour former un noyau plus lourd, tout en libérant de l'énergie. De telles réactions se produisent en permanence au sein des étoiles. Les dispositifs conçus pour exploiter cette énergie sont connus sous le nom de réacteurs à fusion nucléaire.
Bohm diffusionThe diffusion of plasma across a magnetic field was conjectured to follow the Bohm diffusion scaling as indicated from the early plasma experiments of very lossy machines. This predicted that the rate of diffusion was linear with temperature and inversely linear with the strength of the confining magnetic field. The rate predicted by Bohm diffusion is much higher than the rate predicted by classical diffusion, which develops from a random walk within the plasma. The classical model scaled inversely with the square of the magnetic field.
Metamaterial antennaMetamaterial antennas are a class of antennas which use metamaterials to increase performance of miniaturized (electrically small) antenna systems. Their purpose, as with any electromagnetic antenna, is to launch energy into free space. However, this class of antenna incorporates metamaterials, which are materials engineered with novel, often microscopic, structures to produce unusual physical properties. Antenna designs incorporating metamaterials can step-up the antenna's radiated power.
Interchange instabilityThe interchange instability, also known as the Kruskal–Schwarzchild instability or flute instability, is a type of plasma instability seen in magnetic fusion energy that is driven by the gradients in the magnetic pressure in areas where the confining magnetic field is curved. The name of the instability refers to the action of the plasma changing position with the magnetic field lines (i.e. an interchange of the lines of force in space) without significant disturbance to the geometry of the external field.
Spatial resolutionIn physics and geosciences, the term spatial resolution refers to distance between independent measurements, or the physical dimension that represents a pixel of the image. While in some instruments, like cameras and telescopes, spatial resolution is directly connected to angular resolution, other instruments, like synthetic aperture radar or a network of weather stations, produce data whose spatial sampling layout is more related to the Earth's surface, such as in remote sensing and .
Image resolutionImage resolution is the level of detail an holds. The term applies to digital images, film images, and other types of images. "Higher resolution" means more image detail. Image resolution can be measured in various ways. Resolution quantifies how close lines can be to each other and still be visibly resolved. Resolution units can be tied to physical sizes (e.g. lines per mm, lines per inch), to the overall size of a picture (lines per picture height, also known simply as lines, TV lines, or TVL), or to angular subtense.
Tunable metamaterialA tunable metamaterial is a metamaterial with a variable response to an incident electromagnetic wave. This includes remotely controlling how an incident electromagnetic wave (EM wave) interacts with a metamaterial. This translates into the capability to determine whether the EM wave is transmitted, reflected, or absorbed. In general, the lattice structure of the tunable metamaterial is adjustable in real time, making it possible to reconfigure a metamaterial device during operation.
Classical diffusionClassical diffusion is a key concept in fusion power and other fields where a plasma is confined by a magnetic field within a vessel. It considers collisions between ions in the plasma that causes the particles to move to different paths and eventually leave the confinement volume and strike the sides of the vessel. The rate of diffusion scales with 1/B2, where B is the magnetic field strength, implies that confinement times can be greatly improved with small increases in field strength.
Magnetic resonance elastographyMagnetic resonance elastography (MRE) is a form of elastography that specifically leverages MRI to quantify and subsequently map the mechanical properties (elasticity or stiffness) of soft tissue. First developed and described at Mayo Clinic by Muthupillai et al. in 1995, MRE has emerged as a powerful, non-invasive diagnostic tool, namely as an alternative to biopsy and serum tests for staging liver fibrosis. Diseased tissue (e.g. a breast tumor) is often stiffer than the surrounding normal (fibroglandular) tissue, providing motivation to assess tissue stiffness.
Super-résolutionEn traitement du signal et en , la super-résolution désigne le processus qui consiste à améliorer la résolution spatiale, c'est-à-dire le niveau de détail, d'une image ou d'un système d'acquisition. Cela regroupe des méthodes matérielles qui visent à contourner les problèmes optiques et autres difficultés physiques rencontrées lors de l'acquisition d'image, ainsi que des techniques algorithmiques qui, à partir d'une ou de plusieurs images déjà capturées, créent une image de meilleure résolution.
SuperlentilleUne superlentille est une lentille optique élaborée avec des métamatériaux et permettant de distinguer des détails jusqu'à vingt fois inférieurs à la longueur d'onde d'utilisation. Une lentille classique est dite « limitée par la diffraction », c'est-à-dire que l'image la plus petite que l'on pourra obtenir sera toujours une tache d'Airy et donc possède un diamètre dépendant du diamètre de la lentille et de la longueur d'onde d'utilisation, limitant l'utilisation de lentilles classiques en verre optique à l'observation d'objet de quelques centaines de nanomètres.
Pouvoir de résolutionLe pouvoir de résolution, ou pouvoir de séparation, pouvoir séparateur, résolution spatiale, résolution angulaire, exprime la capacité d'un système optique de mesure ou d'observation – les microscopes, les télescopes ou l'œil, mais aussi certains détecteurs, particulièrement ceux utilisés en – à distinguer les détails. Il peut être caractérisé par l'angle ou la distance minimal(e) qui doit séparer deux points contigus pour qu'ils soient correctement discernés.