Construction parasismiquethumb| La Tokyo Skytree, la deuxième plus grande tour au monde (derrière le Burj Khalifa) qui, du haut de ses , a parfaitement résisté au séisme de 2011 de magnitude 9, démontrant l'efficacité des constructions parasismiques japonaises. La construction parasismique ou construction antisismique est la réalisation de bâtiments et infrastructures résistant aux séismes. Elle implique l'étude du comportement des bâtiments et structures sujets à un chargement dynamique de type sismique.
Seismic retrofitSeismic retrofitting is the modification of existing structures to make them more resistant to seismic activity, ground motion, or soil failure due to earthquakes. With better understanding of seismic demand on structures and with our recent experiences with large earthquakes near urban centers, the need of seismic retrofitting is well acknowledged. Prior to the introduction of modern seismic codes in the late 1960s for developed countries (US, Japan etc.) and late 1970s for many other parts of the world (Turkey, China etc.
Seismic analysisSeismic analysis is a subset of structural analysis and is the calculation of the response of a building (or nonbuilding) structure to earthquakes. It is part of the process of structural design, earthquake engineering or structural assessment and retrofit (see structural engineering) in regions where earthquakes are prevalent. As seen in the figure, a building has the potential to 'wave' back and forth during an earthquake (or even a severe wind storm). This is called the 'fundamental mode', and is the lowest frequency of building response.
Aléa sismiquevignette|Ceinture de feu du Pacifique L'aléa sismique est la probabilité qu'un séisme destructeur de caractéristiques données (exprimées en général par des paramètres tels que l’accélération, la période de récurrence, l’intensité, le spectre de réponse...) se produise dans une région donnée pendant une période donnée. Il ne doit pas être confondu avec le risque sismique qui est la probabilité qu'un séisme engendre des destructions et fasse des victimes. Ce risque est une combinaison de .
Seismic loadingSeismic loading is one of the basic concepts of earthquake engineering which means application of an earthquake-generated agitation to a structure. It happens at contact surfaces of a structure either with the ground, or with adjacent structures, or with gravity waves from tsunami. Seismic loading depends, primarily, on: Anticipated earthquake's parameters at the site - known as seismic hazard Geotechnical parameters of the site Structure's parameters Characteristics of the anticipated gravity waves from tsunami (if applicable).
Séismevignette|upright=1.5|Carte de la répartition mondiale des séismes en 2010, montrant leur distribution essentiellement le long des frontières des grandes plaques tectoniques (dorsales dans les océans, ceinture de feu du Pacifique et ceinture alpine sur les continents). Un séisme ou tremblement de terre est une secousse du sol résultant de la libération brusque d'énergie accumulée par les contraintes exercées sur les roches. Cette libération d'énergie se fait par rupture le long d'une faille, généralement préexistante.
Isolement basthumb|Fondation antisimique découplée par isolement bas : appui sur galets caoutchouc en tête de fondation, Municipal Office Building, Glendale. Génie parasismique L’isolement bas est une technique de construction parasismique efficace et peu coûteuse. Son but est de découpler les superstructures des bâtiments de leur partie basse afin de résister aux séismes sans avoir besoin d'une structure extrêmement résistante et dispendieuse.
Imagerie sismiqueL'imagerie sismique est une méthode géophysique d'observation de la subsurface. Elle permet de visualiser les structures géologiques en profondeur grâce à l'analyse des échos d'ondes sismiques. Elle ne doit pas être confondue avec la sismologie, qui est l'étude des ondes sismiques et des séismes pour eux-mêmes. Les ondes sismiques peuvent être d'origines naturelles (séisme) ou artificielles. Le signal initial est généralement issu d'une source prévue pour l'imagerie (camion vibreur, explosif, canon à air, etc.
Earthquake-resistant structuresEarthquake-resistant or aseismic structures are designed to protect buildings to some or greater extent from earthquakes. While no structure can be entirely impervious to earthquake damage, the goal of earthquake engineering is to erect structures that fare better during seismic activity than their conventional counterparts. According to building codes, earthquake-resistant structures are intended to withstand the largest earthquake of a certain probability that is likely to occur at their location.
Sismologiethumb|Station sismologique Basse-Terre au sommet du morne Mazeau en Guadeloupe. La sismologie ou séismologie (ce dernier est un anglicisme de seismology) est une discipline scientifique qui étudie les séismes (tremblements de terre) et la propagation des ondes élastiques (dites ondes sismiques) à l'intérieur de la Terre. La sismologie moderne utilise les concepts de la mécanique newtonienne appliqués à la connaissance de la Terre.
Earthquake warning systemAn earthquake warning system or earthquake early warning system is a system of accelerometers, seismometers, communication, computers, and alarms that is devised for notifying adjoining regions of a substantial earthquake while it is in progress. This is not the same as earthquake prediction, which is currently incapable of producing decisive event warnings. An earthquake is caused by the release of stored elastic strain energy during rapid sliding along a fault.
Seismic vibration controlIn earthquake engineering, vibration control is a set of technical means aimed to mitigate seismic impacts in building and non-building structures. All seismic vibration control devices may be classified as passive, active or hybrid where: passive control devices have no feedback capability between them, structural elements and the ground; active control devices incorporate real-time recording instrumentation on the ground integrated with earthquake input processing equipment and actuators within the structure; hybrid control devices have combined features of active and passive control systems.
Seismic intensity scalesSeismic intensity scales categorize the intensity or severity of ground shaking (quaking) at a given location, such as resulting from an earthquake. They are distinguished from seismic magnitude scales, which measure the magnitude or overall strength of an earthquake, which may, or perhaps may not, cause perceptible shaking. Intensity scales are based on the observed effects of the shaking, such as the degree to which people or animals were alarmed, and the extent and severity of damage to different kinds of structures or natural features.
AmortisseurUn amortisseur est un système mécanique destiné à atténuer la force d'un choc ou l’amplitude des oscillations d'un objet en amortissant ses vibrations, généralement par dissipation d'énergie. De nombreux phénomènes physiques peuvent être utilisés pour absorber l’énergie cinétique de l’objet en mouvement : pertes de charge d'un fluide, frottement, comportement hystérétique Cette énergie est souvent transformée en énergie thermique mais peut être convertie dans une autre forme, par exemple électrique.
Flambagethumb|Flexion sous un effort de compression. Le flambage ou flambement est un phénomène d'instabilité d'une structure élastique qui pour échapper à une charge importante exploite un mode de déformation non sollicité, opposant moins de raideur à la charge. La notion de flambement s'applique généralement à des poutres élancées qui lorsqu'elles sont soumises à un effort normal de compression, ont tendance à fléchir et se déformer dans une direction perpendiculaire à l'axe de compression (passage d'un état de compression à un état de flexion) ; mais elle peut aussi s'appliquer par exemple à des lames de ressort sollicitées en flexion qui se déversent en torsion pour échapper à la charge.
Torsional vibrationTorsional vibration is the angular vibration of an object - commonly a shaft - along its axis of rotation. Torsional vibration is often a concern in power transmission systems using rotating shafts or couplings, where it can cause failures if not controlled. A second effect of torsional vibrations applies to passenger cars. Torsional vibrations can lead to seat vibrations or noise at certain speeds. Both reduce the comfort.
Séisme lentUn séisme lent (SSE, pour slow slip event) appelé aussi séisme silencieux, est un déplacement discontinu semblable à celui d'un séisme, mais qui libère l'énergie élastique en plusieurs heures ou plusieurs jours au lieu de quelques minutes comme un séisme ordinaire. Les séismes lents ont d'abord été détectés par la mesure des déplacements et déformations. Aujourd'hui l'on sait qu'ils sont généralement accompagnés d'écoulements fluides et du trémor associé, que l'on peut détecter et localiser par filtrage des données sismométriques (dans la bande , typiquement).
Suspension de véhiculeLes suspensions d'un véhicule sont les éléments permettant de relier les masses non suspendues (typiquement la roue, les pièces d'entraînement de roue, souvent les systèmes de freinage, etc) aux masses suspendues (typiquement le châssis, le moteur et tous les composants du véhicule fixés au châssis). L'utilisation de la suspension est imposée par les irrégularités de la surface sur laquelle se déplace le véhicule.
Structural loadA structural load or structural action is a force, deformation, or acceleration applied to structural elements. A load causes stress, deformation, and displacement in a structure. Structural analysis, a discipline in engineering, analyzes the effects of loads on structures and structural elements. Excess load may cause structural failure, so this should be considered and controlled during the design of a structure. Particular mechanical structures—such as aircraft, satellites, rockets, space stations, ships, and submarines—are subject to their own particular structural loads and actions.
Calcul des structures et modélisationLe calcul des structures et la modélisation concernent deux domaines distincts : d'une part les applications spécifiques au patrimoine architectural, mobilier et naturel et d'autre part les applications industrielles. Le calcul des structures et leur modélisation est utilisé dans les domaines : de la conservation et mise en valeur du patrimoine architectural, mobilier et naturel, dans le cadre de missions d’assistance à la maître d’œuvre ou au maître d’ouvrage permettant d’arrêter un programme de travaux, d’applications industrielles.