The turbine components of a gas turbine need extensive cooling to withstand the high heat loads generated by the flow of the hot combustion gases. The leading edge of a turbine blade is one of the areas that faces the hottest gas flow conditions and is thus one of the most critical areas to be cooled. The stagnation region of turbine airfoils is generally cooled with showerhead cooling scheme, which consist in injecting coolant onto the stagnation region through closely spaced rows of film cooling holes. This provides convective cooling inside the holes and produces a layer of coolant film on the external surface. The objective of this study is to investigate experimentally the influence of mainstream incidence on showerhead film cooling. The film cooling effectiveness and heat transfer coefficient were thus measured on a series of symmetric blunt bodies with different showerhead configurations simulating the leading edge of turbine airfoils. Tests have been performed at 0° on-design and 5° off-design mainstream incidences at an approach Mach number of 0.26. Besides the mainstream incidence angle, the investigated parameters were the blowing ratio, the wedge angle, the row location, the spanwise pitch between the holes and the hole shape. In addition to the film cooling measurements, baseline heat transfer tests were performed on test models without film cooling holes in order to evaluate the film cooling performances. To characterize the mainflow conditions and the velocity profile on the test models, aerodynamic measurements have also been carried out. The heat transfer measurements have been performed using the transient liquid crystal technique. The transient experiments were generated by a pre-conditioning system and a rapid insertion mechanism. The data analysis was adapted to measurements on highly curved surfaces using the approximate analytical solution of the heat conduction into a solid cylinder with convective boundary conditions on the surface. Time-varying adiabatic wall temperatures were accounted for using Duhamel's superposition theorem. The first tested showerhead geometry was a triangular blunt body representative of a turbine rotor blade showerhead with a circular leading edge, a 21.1° wedge angle and two film cooling rows. Because of jet lift-off, the film cooling performances of this two-row configuration were relatively low and were almost unaffected by the increase of blowing ratio from 1.5 to 3.9. The heat transfer coefficient was found to be greatly increased at the row location in comparison to the case without film cooling. At 5° off-design incidence angle, the stagnation line moves passed the pressure side row. The two rows were then located on the same side of the stagnation line and were both blowing towards the suction side. On the suction side the film cooling protection was thus very good due to film accumulation but the pressure side was left almost unprotected resulting in highly asymmetric film cooling perform
Luc Girardin, François Maréchal, Raphaël Briguet, Ana Catarina Gouveia Braz, Bingqian Liu
Lyesse Laloui, Elena Ravera, Sofie Elaine ten Bosch