Output impedanceThe output impedance of an electrical network is the measure of the opposition to current flow (impedance), both static (resistance) and dynamic (reactance), into the load network being connected that is internal to the electrical source. The output impedance is a measure of the source's propensity to drop in voltage when the load draws current, the source network being the portion of the network that transmits and the load network being the portion of the network that consumes.
Input impedanceThe input impedance of an electrical network is the measure of the opposition to current (impedance), both static (resistance) and dynamic (reactance), into a load network that is external to the electrical source network. The input admittance (the reciprocal of impedance) is a measure of the load network's propensity to draw current. The source network is the portion of the network that transmits power, and the load network is the portion of the network that consumes power.
Impédance (électricité)L'impédance électrique mesure l'opposition d'un circuit électrique au passage d'un courant alternatif sinusoïdal. La définition de l'impédance est une généralisation de la loi d'Ohm au courant alternatif. On passe de à , mais avec et de formes sinusoïdales. Le mot impédance fut inventé par Oliver Heaviside en . Il vient du verbe anglais en signifiant « retenir », « faire obstacle à » ; verbe qui dérive lui-même du latin impedire qui veut dire « entraver ».
MicrofluidiqueLa microfluidique est la science et la technique des systèmes manipulant des fluides et dont au moins l'une des dimensions caractéristiques est de l'ordre du micromètre. George Whitesides définit la microfluidique comme « la science et la technologie des systèmes qui manipulent de petits volumes de fluides ( à ), en utilisant des canaux de la dimension de quelques dizaines de micromètres ». Selon Patrick Tabeling, Tabeling précise qu'il entend essentiellement par « nouvelles techniques » la microfabrication héritée de la micro-électronique.
Paper-based microfluidicsPaper-based microfluidics are microfluidic devices that consist of a series of hydrophilic cellulose or nitrocellulose fibers that transport fluid from an inlet through the porous medium to a desired outlet or region of the device, by means of capillary action. This technology builds on the conventional lateral flow test which is capable of detecting many infectious agents and chemical contaminants. The main advantage of this is that it is largely a passively controlled device unlike more complex microfluidic devices.
Droplet-based microfluidicsDroplet-based microfluidics manipulate discrete volumes of fluids in immiscible phases with low Reynolds number and laminar flow regimes. Interest in droplet-based microfluidics systems has been growing substantially in past decades. Microdroplets offer the feasibility of handling miniature volumes (μl to fl) of fluids conveniently, provide better mixing, encapsulation, sorting, sensing and are suitable for high throughput experiments.
Marine microorganismsMarine microorganisms are defined by their habitat as microorganisms living in a marine environment, that is, in the saltwater of a sea or ocean or the brackish water of a coastal estuary. A microorganism (or microbe) is any microscopic living organism or virus, that is too small to see with the unaided human eye without magnification. Microorganisms are very diverse. They can be single-celled or multicellular and include bacteria, archaea, viruses and most protozoa, as well as some fungi, algae, and animals, such as rotifers and copepods.
Adaptation d'impédancesL’adaptation d'impédances est une technique utilisée en électricité permettant d'optimiser le transfert d'une puissance électrique entre un émetteur (source) et un récepteur électrique (charge) et d'optimiser la transmission des signaux de télécommunications. la théorie de la puissance maximale détermine que l'impédance de la charge doit être le complexe conjugué de l'impédance du générateur ; dans les lignes de transmission, l'impédance caractéristique est une sorte de perméabilité du milieu qui cause des réflexions quand elle change (comme en optique ou en acoustique) et qui deviennent gênantes quand la longueur de la ligne approche une fraction non négligeable de la longueur d'onde du signal.
Laboratoire sur puceUn laboratoire sur puce est un dispositif intégré rassemblant, sur un substrat miniaturisé, une ou plusieurs fonctions de laboratoire. L'analyse du vivant regroupe trois des quatre raisons majeures ayant entraîné le développement de la microfluidique ; elle représente par conséquent une large part des applications. On considère généralement que le premier dispositif microfluidique d'analyse est celui développé par Terry et al. ; ceux-ci réalisent en 1979 un système miniaturisé d'analyse de gaz par chromatographie sur un substrat de silicium.
Microbille de plastiqueLes microbilles de plastique () sont des particules sphériques de plastique composées de polymères synthétiques (résines et/ou copolymères). Elles sont de plus en plus utilisées depuis les années 1990 par l'industrie des cosmétiques. Ce sont alors des plastiques réputés non toxiques et non irritants pour l'être humain, mais qui posent problèmes quand ils sont diffusés dans l'environnement.
Plancton aérienLe plancton aérien (ou aéroplancton) est l'équivalent aérien (atmosphérique) du plancton marin. Il est constitué de l'ensemble des petits animaux volant (ou se laissant dériver) dans les masses d'air. thumb|upright=1.5|Plancton aérien au-dessus de la Loire à Meung-sur-Loire. thumb|upright=1.5|Photo instantanée (avec flash) montrant mieux, sur le même site que ci-dessus, et au même moment les différentes tailles d'insectes attirés par le halo lumineux.
Organ-on-a-chipAn organ-on-a-chip (OOC) is a multi-channel 3-D microfluidic cell culture, integrated circuit (chip) that simulates the activities, mechanics and physiological response of an entire organ or an organ system. It constitutes the subject matter of significant biomedical engineering research, more precisely in bio-MEMS. The convergence of labs-on-chips (LOCs) and cell biology has permitted the study of human physiology in an organ-specific context.
Micro-organismeUn micro-organisme ou microorganisme (du grec μικρός, mikrós, « petit » et de ὀργανισμός, organismós, « organisme ») ou microbe (du grec μικρός, mikrós, « petit » et βίος, bíos, « vie ») est un organisme vivant qui, individuellement invisible à l'œil nu, ne peut être observé qu'à l'aide d'un microscope. Ce sont tous des organismes unicellulaires. Les trois domaines du vivant sont représentés parmi les microorganismes : bactéries, archées et eucaryotes unicellulaires (protistes et champignons).
Microplastiquethumb|upright=1.4|Micro-plastiques bleus découverts dans un saladier lors du rinçage ; provenant de la partie abrasive de l’éponge synthétique. Les microplastiques sont les petites particules (< 5 mm) de matière plastique dispersées dans l'environnement. Ils sont devenus un sujet de préoccupation car ils s'accumulent dans les sols, les cours d'eau, les lacs et l'environnement marin et certains aliments (bivalves filtreurs et produits de la pêche notamment) ; ils ont en quelques décennies contaminé tous les océans et les espèces marines à tous les niveaux de la chaîne alimentaire, d'un pôle à l'autre et jusque dans les grands fonds.
Cytométrievignette|Les cytomètres sont des instruments qui permettent de compter les cellules sanguines dans un test de sang La cytométrie est la mesure des caractéristiques des cellules. Les variables qui peuvent être mesurées par des méthodes cytométriques comprennent la taille des cellules, le nombre de cellules, la morphologie des cellules (forme et structure), la phase du cycle cellulaire, l'ADN contenu et l'existence ou l'absence de certaines protéines sur la surface de la cellule ou dans le cytoplasme.
Récepteur radioUn récepteur radio, aussi appelé simplement radio ou poste de radio, est un appareil électronique destiné à capter, sélectionner et décoder les ondes radioélectriques émises par les émetteurs radio. La fonction de décodage consiste à extraire des ondes captées, les informations qui y ont été incorporées lors de l'émission : sons ou signaux numériques (RDS, DRM, DAB, signaux horaires). Le terme « radio » provient de la simplification de l'expression « récepteur d’émissions diffusées par ondes radiophoniques ».
Plastic pellet pollutionPlastic pellet pollution is a type of marine debris originating from the plastic particles that are universally used to manufacture large-scale plastics. In the context of plastic pollution, these pre-production plastic pellets are commonly known as 'nurdles'. These microplastics are created separately from the user plastics they are melted down to form, and pellet loss can occur during both the manufacturing and transport stages. When released into the open environment, they create persistent pollution both in the oceans and on beaches.
Arbre couvrant de poids minimalthumb|L'arbre couvrant de poids minimal d'un graphe planaire. Chaque arête est identifiée avec son poids qui, ici, est approximativement sa longueur. En théorie des graphes, étant donné un graphe non orienté connexe dont les arêtes sont pondérées, un arbre couvrant de poids minimal (ACM), arbre couvrant minimum ou arbre sous-tendant minimum de ce graphe est un arbre couvrant (sous-ensemble qui est un arbre et qui connecte tous les sommets ensemble) dont la somme des poids des arêtes est minimale (c'est-à-dire de poids inférieur ou égal à celui de tous les autres arbres couvrants du graphe).
Cell countingCell counting is any of various methods for the counting or similar quantification of cells in the life sciences, including medical diagnosis and treatment. It is an important subset of cytometry, with applications in research and clinical practice. For example, the complete blood count can help a physician to determine why a patient feels unwell and what to do to help. Cell counts within liquid media (such as blood, plasma, lymph, or laboratory rinsate) are usually expressed as a number of cells per unit of volume, thus expressing a concentration (for example, 5,000 cells per milliliter).
Compteur Coultervignette|droite|Un compteur Coulter Un compteur Coulter est un appareil destiné à compter les particules et les cellules, et à en mesurer la taille. On l'utilise par exemple pour les bactéries, ou pour l'analyse de la distribution de la taille des particules dans la mesure de la qualité de l'air. Le compteur Coulter est commercialisé depuis les années 1950. Le compteur détecte le changement de la résistance électrique lorsque l'on fait passer un électrolyte contenant des particules ou des cellules au travers d'une petite ouverture que l'on peut calibrer.