Tandem mass spectrometryTandem mass spectrometry, also known as MS/MS or MS2, is a technique in instrumental analysis where two or more mass analyzers are coupled together using an additional reaction step to increase their abilities to analyse chemical samples. A common use of tandem MS is the analysis of biomolecules, such as proteins and peptides. The molecules of a given sample are ionized and the first spectrometer (designated MS1) separates these ions by their mass-to-charge ratio (often given as m/z or m/Q).
Spectrométrie de massethumb|right|Spectromètre de masse La spectrométrie de masse est une technique physique d'analyse permettant de détecter et d'identifier des molécules d’intérêt par mesure de leur masse, et de caractériser leur structure chimique. Son principe réside dans la séparation en phase gazeuse de molécules chargées (ions) en fonction de leur rapport masse/charge (m/z). Elle est utilisée dans pratiquement tous les domaines scientifiques : physique, astrophysique, chimie en phase gazeuse, chimie organique, dosages, biologie, médecine, archéologie.
Spectrométrie de masse à trappe orbitaleLa spectrométrie de masse à trappe orbitale consiste en l'utilisation d'un Orbitrap (nom commercial) qui permet le piégeage des ions par un champ électrostatique. Ces ions possèdent une fréquence d'oscillation axiale variable en fonction de leur ratio masse sur charge, ce qui permet de les séparer. L'Orbitrap est composée d'une électrode centrale ainsi qu'une électrode externe en forme de cylindre. L'électrode centrale coaxiale à l'axe interne piège les ions dans un mouvement orbitale.
Spectrométrie de masse des ions secondairesLa spectrométrie de masse des ions secondaires est un procédé d'analyse de surface connu sous le nom de SIMS, d'après l'acronyme anglais signifiant secondary ion mass spectrometry, qui consiste à bombarder la surface de l'échantillon à analyser avec un faisceau d'ions. L'échantillon est alors pulvérisé, et une partie de la matière pulvérisée est ionisée. Ces ions secondaires sont alors accélérés vers un spectromètre de masse qui permettra de mesurer la composition élémentaire, isotopique ou moléculaire de la surface de l'échantillon.
Rapport signal sur bruitEn électronique, le rapport signal sur bruit (SNR, ) est le rapport des puissances entre la partie du signal qui représente une information et le reste, qui constitue un bruit de fond. Il est un indicateur de la qualité de la transmission d'une information. L'expression d'un rapport signal sur bruit se fonde implicitement sur le principe de superposition, qui pose que le signal total est la somme de ces composantes. Cette condition n'est vraie que si le phénomène concerné est linéaire.
Proton-transfer-reaction mass spectrometryProton-transfer-reaction mass spectrometry (PTR-MS) is an analytical chemistry technique that uses gas phase hydronium reagent ions which are produced in an ion source. PTR-MS is used for online monitoring of volatile organic compounds (VOCs) in ambient air and was developed in 1995 by scientists at the Institut für Ionenphysik at the Leopold-Franzens University in Innsbruck, Austria. A PTR-MS instrument consists of an ion source that is directly connected to a drift tube (in contrast to SIFT-MS no mass filter is interconnected) and an analyzing system (quadrupole mass analyzer or time-of-flight mass spectrometer).
Chromatographie en phase liquide-spectrométrie de masseLa chromatographie en phase liquide couplée à la spectrométrie de masse (en anglais Liquid chromatography-mass spectrometry ou LC-MS) est une méthode d'analyse qui combine les performances de la chromatographie en phase liquide et de la spectrométrie de masse afin d'identifier et/ou de quantifier précisément de nombreuses substances. Une unité LC-MS est composée de deux blocs principaux : un chromatographe en phase liquide et un spectromètre de masse. Catégorie:Méthode de la biochimie Catégorie:Chromatogra
Désorption-ionisation laser assistée par matriceLa désorption-ionisation laser assistée par matrice (en anglais en ou MALDI) est une technique d'ionisation douce utilisée en spectrométrie de masse. Elle permet l'ionisation et la vaporisation de biomolécules comme des biopolymères des protéines, des peptides ou des sucres et de grosses molécules organiques comme les polymères, les dendrimères et autres macromolécules. Ces molécules ont tendance à se fragmenter lorsqu'elles sont ionisées par des méthodes plus conventionnelles.
Carrier-to-noise ratioIn telecommunications, the carrier-to-noise ratio, often written CNR or C/N, is the signal-to-noise ratio (SNR) of a modulated signal. The term is used to distinguish the CNR of the radio frequency passband signal from the SNR of an analog base band message signal after demodulation. For example, with FM radio, the strength of the 100 MHz carrier with modulations would be considered for CNR, whereas the audio frequency analogue message signal would be for SNR; in each case, compared to the apparent noise.
Séquençage de l'ADNcadre|Résultat du séquençage par la méthode de Sanger. L'ordre de chaque bande indique la position d'un nucléotide A,T,C ou G Le séquençage de l'ADN consiste à déterminer l'ordre d'enchaînement des nucléotides pour un fragment d’ADN donné. La séquence d’ADN contient l’information nécessaire aux êtres vivants pour survivre et se reproduire. Déterminer cette séquence est donc utile aussi bien pour les recherches visant à savoir comment vivent les organismes que pour des sujets appliqués.
Mass spectral interpretationMass spectral interpretation is the method employed to identify the chemical formula, characteristic fragment patterns and possible fragment ions from the mass spectra. Mass spectra is a plot of relative abundance against mass-to-charge ratio. It is commonly used for the identification of organic compounds from electron ionization mass spectrometry. Organic chemists obtain mass spectra of chemical compounds as part of structure elucidation and the analysis is part of many organic chemistry curricula.
Electron ionizationElectron ionization (EI, formerly known as electron impact ionization and electron bombardment ionization) is an ionization method in which energetic electrons interact with solid or gas phase atoms or molecules to produce ions. EI was one of the first ionization techniques developed for mass spectrometry. However, this method is still a popular ionization technique. This technique is considered a hard (high fragmentation) ionization method, since it uses highly energetic electrons to produce ions.
Whole genome sequencingWhole genome sequencing (WGS), also known as full genome sequencing, complete genome sequencing, or entire genome sequencing, is the process of determining the entirety, or nearly the entirety, of the DNA sequence of an organism's genome at a single time. This entails sequencing all of an organism's chromosomal DNA as well as DNA contained in the mitochondria and, for plants, in the chloroplast. Whole genome sequencing has largely been used as a research tool, but was being introduced to clinics in 2014.
Interaction protéine-protéinethumb|upright=1.2|L'inhibiteur de la ribonucléase en forme de fer à cheval (en représentation « fil de fer ») forme une interaction protéine–protéine avec la protéine de la ribonucléase. Les contacts entre les deux protéines sont représentés sous forme de taches colorées. Une Interaction protéine–protéine apparait lorsque deux ou plusieurs protéines se lient entre elles, le plus souvent pour mener à bien leur fonction biologique.
Ion trapAn ion trap is a combination of electric and/or magnetic fields used to capture charged particles — known as ions — often in a system isolated from an external environment. Atomic and molecular ion traps have a number of applications in physics and chemistry such as precision mass spectrometry, improved atomic frequency standards, and quantum computing. In comparison to neutral atom traps, ion traps have deeper trapping potentials (up to several electronvolts) that do not depend on the internal electronic structure of a trapped ion.
Bruit de mesureEn métrologie, le bruit de mesure est l'ensemble des signaux parasites qui se superposent au signal que l'on cherche à obtenir au moyen d'une mesure d'un phénomène physique. Ces signaux sont une gêne pour la compréhension de l'information que le signal transporte. La métrologie vise donc notamment à connaître leurs origines et à les caractériser, afin de les éliminer et d'obtenir le signal d'origine aussi distinctement que possible. La source du bruit d'origine externe est externe au système physique générant le signal utile et agit par influence sur celui-ci.
Séquençage des protéinesLe séquençage des protéines est la détermination de la séquence polypeptidique. Elle est destinée à connaître le nombre, la nature chimique et l'ordre de tous les résidus d'acides aminés dans un polypeptide. Pour cela, si la protéine contient plus d'une chaîne polypeptidique, les chaînes doivent être d'abord séparées, puis purifiées. Généralement, toutes les liaisons disulfures seront réduites et les thiols ainsi obtenus alkylés.
Ion-mobility spectrometry–mass spectrometryIon mobility spectrometry–mass spectrometry (IMS-MS) is an analytical chemistry method that separates gas phase ions based on their interaction with a collision gas and their masses. In the first step, the ions are separated according to their mobility through a buffer gas on a millisecond timescale using an ion mobility spectrometer. The separated ions are then introduced into a mass analyzer in a second step where their mass-to-charge ratios can be determined on a microsecond timescale.
Progrès techniqueLe progrès technique est l’amélioration des techniques, y compris organisationnelles, qui sont utilisées dans le processus de production des biens et des services. Le développement des « nouvelles technologies » est tel que l'on parle de progrès technique. Le concept de progrès technique est toutefois controversé dans les milieux écologistes en raison de certains effets négatifs sur l'environnement du développement technologique tel qu'il s'opère depuis la révolution industrielle.
Noise (signal processing)In signal processing, noise is a general term for unwanted (and, in general, unknown) modifications that a signal may suffer during capture, storage, transmission, processing, or conversion. Sometimes the word is also used to mean signals that are random (unpredictable) and carry no useful information; even if they are not interfering with other signals or may have been introduced intentionally, as in comfort noise. Noise reduction, the recovery of the original signal from the noise-corrupted one, is a very common goal in the design of signal processing systems, especially filters.