Publication
This contribution presents an isotropic magnetic field probe with shaped frequency response in the band 100 kHz - 400 MHz to ponder the aggregate response according to the ICNIRP 2020 guidelines. The basic sensor is a printed loop which is modelled as a Thévenin source obtained through full-wave simulation. A canonical filter is optimized considering the frequency response of the equivalent source, the detector and the desired transfer function. Finally, a cubic arrangement of three elementary sensors is used to assess the isotropy and isolation of the probe.
Drazen Dujic, Tianyu Wei, Andrea Cervone
Alireza Karimi, Elias Sebastian Klauser, Vaibhav Gupta
German Augusto Ramirez Arroyave